Files
FPGA---VHDL/project_7/project_5.srcs/sources_1/new/clock_logic.vhd

179 lines
5.8 KiB
VHDL

-- clock_logic.vhd
library IEEE;
use IEEE.STD_LOGIC_1164.ALL;
-- Uncomment the following library declaration if using
-- arithmetic functions with Signed or Unsigned values
--use IEEE.NUMERIC_STD.ALL;
-- Uncomment the following library declaration if instantiating
-- any Xilinx leaf cells in this code.
--library UNISIM;
--use UNISIM.VComponents.all;
entity clock_logic is
Port (
CLK : in STD_LOGIC;
RST : in STD_LOGIC;
CE_1HZ : in STD_LOGIC; -- Enable signal from the divider
SW_DIN : in STD_LOGIC_VECTOR (3 downto 0);
BTN_LOAD : in STD_LOGIC_VECTOR (3 downto 0);
-- Outputs to the top module/display
S_UNITS : out STD_LOGIC_VECTOR (3 downto 0);
S_TENS : out STD_LOGIC_VECTOR (3 downto 0);
M_UNITS : out STD_LOGIC_VECTOR (3 downto 0);
M_TENS : out STD_LOGIC_VECTOR (3 downto 0);
H_UNITS : out STD_LOGIC_VECTOR (3 downto 0);
H_TENS : out STD_LOGIC_VECTOR (3 downto 0)
);
end clock_logic;
architecture Behavioral of clock_logic is
component counter is
Generic ( MAX_LIMIT : STD_LOGIC_VECTOR(3 downto 0) := "1001" ); -- Default to 9
Port ( CLK : in STD_LOGIC;
CE : in STD_LOGIC;
PE : in STD_LOGIC;
DIN : in STD_LOGIC_VECTOR(3 downto 0);
RST : in STD_LOGIC;
TC : out STD_LOGIC;
COUNT_OUT : out STD_LOGIC_VECTOR (3 downto 0));
end component;
-- Internal signals to connect the counters
signal sig_s_units, sig_s_tens : std_logic_vector(3 downto 0);
signal sig_m_units, sig_m_tens : std_logic_vector(3 downto 0);
signal sig_h_units, sig_h_tens : std_logic_vector(3 downto 0);
-- Carry signals (TC)
signal tc_su, tc_st, tc_mu, tc_mt, tc_hu : std_logic;
-- Reset for hours (to handle the 24 reset)
signal hour_reset : std_logic;
-- Specific load enable signals that check for boundaries
signal load_h_tens, load_h_units : std_logic;
signal load_m_tens, load_m_units : std_logic;
-- Internal signals for the "Safe" load triggers
signal safe_load_su, safe_load_st : std_logic;
signal safe_load_mu, safe_load_mt : std_logic;
signal safe_load_hu, safe_load_ht : std_logic;
begin
-- MINUTES CONSTRAINTS (Max 59)
load_m_units <= BTN_LOAD(0) when (SW_DIN <= "1001") else '0'; -- 0-9
load_m_tens <= BTN_LOAD(1) when (SW_DIN <= "0101") else '0'; -- 0-5
-- HOURS CONSTRAINTS (Max 23)
-- Rule A: Cannot load Tens > 2.
-- Rule B: If Tens is 2, cannot load Units > 3.
-- Rule C: If Units is > 3, cannot load Tens into 2.
load_h_tens <= BTN_LOAD(3) when (
SW_DIN < "0010" or
(SW_DIN = "0010" and sig_h_units <= "0011")
) else '0';
load_h_units <= BTN_LOAD(2) when (
(sig_h_tens < "0010" and SW_DIN <= "1001") or
(sig_h_tens = "0010" and SW_DIN <= "0011")
) else '0';
-------------------------------------------------------
-- SECONDS SECTION
-- SECONDS UNITS (0-9) - Triggered by the 1Hz pulse
U_CNT_SEC_UNITS : counter
generic map ( MAX_LIMIT => "1001" ) -- do 9
port map (
CLK => CLK, RST => RST, CE => CE_1HZ,
PE => '0', DIN => "0000", -- Seconds usually don't need manual load
TC => tc_su, COUNT_OUT => sig_s_units
);
-- SECONDS TENS (0-5) - Triggered when Sec Units reach 9
U_CNT_SEC_TENS : counter
generic map ( MAX_LIMIT => "0101" ) -- do 5
port map (
CLK => CLK, RST => RST, CE => tc_su,
PE => '0', DIN => "0000",
TC => tc_st, COUNT_OUT => sig_s_tens
);
-------------------------------------------------------
-- MINUTES SECTION
-- MINUTES UNITS (0-9) - When Seconds reach 59
U_CNT_MIN_UNITS : counter
generic map ( MAX_LIMIT => "1001" ) -- do 9
port map (
CLK => CLK,
RST => RST,
CE => tc_st,
PE => load_m_units,
DIN => SW_DIN,
TC => tc_mu,
COUNT_OUT => sig_m_units
);
-- MINUTES TENS (0-5)
U_CNT_MIN_TENS : counter
generic map ( MAX_LIMIT => "0101" ) -- do 5
port map (
CLK => CLK,
RST => RST,
CE => tc_mu,
PE => load_m_tens,
DIN => SW_DIN,
TC => tc_mt,
COUNT_OUT => sig_m_tens
);
-------------------------------------------------------
-- HOURS SECTION
-- If we are at 23:59:59, the next tick should reset hours
process(sig_h_tens, sig_h_units, tc_mt, RST)
begin
if RST = '1' then
hour_reset <= '1';
elsif (sig_h_tens = "0010" and sig_h_units = "0011" and tc_mt = '1') then
hour_reset <= '1';
else
hour_reset <= '0';
end if;
end process;
-- HOURS UNITS (0-9)
U_CNT_HOR_UNITS : counter
generic map ( MAX_LIMIT => "1001" ) -- To 9
port map (
CLK => CLK,
RST => hour_reset,
CE => tc_mt,
PE => load_h_units,
DIN => SW_DIN,
TC => tc_hu,
COUNT_OUT => sig_h_units
);
-- HOURS TENS (0-2)
U_CNT_HOR_TENS : counter
generic map ( MAX_LIMIT => "0010" ) -- To 2
port map (
CLK => CLK,
RST => hour_reset,
CE => tc_hu,
PE => load_h_tens,
DIN => SW_DIN,
TC => open,
COUNT_OUT => sig_h_tens
);
-- Drive output ports
S_UNITS <= sig_s_units;
S_TENS <= sig_s_tens;
M_UNITS <= sig_m_units;
M_TENS <= sig_m_tens;
H_UNITS <= sig_h_units;
H_TENS <= sig_h_tens;
end Behavioral;