I now have the full official Schneider Electric datasheet. Here is **everything** you need to know about the **SR1 B201BD** (Zelio Logic Smart Relay) — inputs and outputs only, with discrete values, sourced from the official Schneider Electric File 8501 catalog document. --- ## 🔷 IDENTIFICATION The **SR1 B201BD** is a **Zelio-Logic™ Smart Relay** by Schneider Electric (Telemecanique). It is a **24 Vdc powered** unit with **12 inputs / 8 outputs**, with a clock, **not** a blind version. **Source:** Schneider Electric File 8501, Ordering Information table, page 13. --- ## 🔷 INPUTS — Full Breakdown ### 1. Number & Type of Inputs The SR1B201BD has **12 discrete 24 Vdc inputs** labeled **I1 through IA** (i.e., I1, I2, I3, I4, I5, I6, I7, I8, I9, IA), plus **2 analog inputs** labeled **IB and IC**. These are connected via **screw terminals**. **Source:** Ordering Information table + Wiring Diagram, pages 13–15. --- ### 2. Discrete Inputs (I1 to IA) — Exact Electrical Specs | Parameter | Value | |---|---| | **Nominal input voltage** | **24 Vdc** | | **Nominal input current** | **3 mA** | | **State 1 (ON) — Voltage threshold** | **≥ 15 V** | | **State 1 (ON) — Current threshold** | **> 1.8 mA** | | **State 0 (OFF) — Voltage threshold** | **< 5 V** | | **State 0 (OFF) — Current threshold** | **< 0.5 mA** | | **Input impedance at State 1** | **8 kΩ** | | **Response time — State 0 → 1** | **0.3 ms (Fast) … 3 ms (Slow)** | | **Response time — State 1 → 0** | **0.5 ms (Fast) … 5 ms (Slow)** | | **Conformity** | IEC 1131-2, **Type 1** | | **Sensor compatibility** | **3-wire PNP only** | | **2-wire sensors** | **Not supported** | | **Input type** | **Resistive** | | **Isolation (supply to inputs)** | **None** | | **Isolation (between inputs)** | **None** | | **Maximum counting frequency** | **60 Hz** | **Source:** "Discrete 24 Vdc Input Characteristics" table, page 9 — column SR1-ppppBD (inputs I1 to IA). --- ### 3. Analog Inputs (IB and IC) — Exact Specs | Parameter | Value | |---|---| | **Number of analog channels** | **2** (IB and IC) | | **Voltage range** | **0–10 Vdc** | | **Input impedance** | **62.5 kΩ at 10 V** | | **Maximum non-destructive voltage** | **±30 V** | | **Resolution** | **8 bits** | | **Conversion time** | **Relay cycle time** | | **Precision @ 25°C** | **±1.6% of full range** | | **Precision @ 60°C** | **±2.9% of full range** | | **Repeat accuracy @ 55°C** | **< 0.1% of full range** | | **Isolation (analog channel to supply)** | **None** | | **Max wiring distance** | **10 m maximum with shielded cable** | **Source:** "Integral Analog Input Characteristics" table, page 10 — column SR1-BpppBD. --- ### 4. Analog Input Logic Functions (IB/IC used as discrete triggers) Seven comparison functions can be performed on the analog inputs IB and IC to generate discrete contact outputs A1: - **Analog 1:** A1 closes when IB **≤ reference voltage** - **Analog 2:** A1 closes when IB **≥ reference voltage** - **Analog 3:** A1 closes when IC **≤ reference voltage** - **Analog 4:** A1 closes when IC **≥ reference voltage** - **Analog 5:** A1 closes when IB **≤ IC** - **Analog 6:** A1 closes when IB **≥ IC** - **Analog 7:** A1 closes when IB is **within the window IC−H to IC+H** (hysteresis band) **Source:** "Overview of Functions — Analog Inputs" section, page 6. --- ### 5. Front Panel Arrow Keys as Inputs The 4 arrow keys on the front of the relay **can be used as inputs** (push buttons) in the program. **Source:** "Overview of Functions," page 6. --- ## 🔷 OUTPUTS — Full Breakdown ### 1. Number & Type of Outputs The SR1B201BD has **8 relay outputs** (labeled Q1–Q8), **without common potential** between them. Contact type is **N.O. (Normally Open)**. **Source:** "Relay Output Characteristics" table, page 10 — column SR1-p201BD. --- ### 2. Relay Output Electrical Specs | Parameter | Value | |---|---| | **Number of outputs** | **8** (no common potential) | | **Contact type** | **N.O. (Normally Open)** | | **Operating voltage range** | **5–150 Vdc or 24–250 Vac** | | **Thermal current (max load)** | **8 A** | | **Min switching capacity** | **10 mA at 5 V minimum** | | **Low power switching reliability** | **17 V / 5 mA; 1 failure per 100 million cycles** | | **Maximum operating rate (no load)** | **10 Hz** | | **Maximum operating rate (at rated current)** | **0.5 Hz** | | **Mechanical life** | **10 million operating cycles** | | **Rated impulse withstand voltage** | **2.5 kV (per IEC 60947-1)** | | **Response time — Trip** | **10 ms** | | **Response time — Reset** | **5 ms** | | **Short-circuit protection** | **None** | | **Overvoltage/overload protection** | **None** | **Source:** "Relay Output Characteristics" table, page 10. --- ### 3. Output Electrical Durability (500,000 cycle ratings) | Load Category | Conditions | Max Current | |---|---|---| | **DC-12** | Resistive / solid-state loads at 24 Vdc | **1.5 A** | | **DC-13** | Inductive (electromagnets), L/R = 10 ms, 24 Vdc | **0.6 A** | | **AC-12** | Resistive / solid-state loads at 230 Vac | **1.5 A** | | **AC-15** | Inductive loads >72 VA at 230 Vac | **0.9 A** | **Source:** "Relay Output Characteristics — Electrical Durability" table, page 10. --- ### 4. Output Terminal Wiring Specs | Parameter | Value | |---|---| | **Screwdriver size** | Ø 3.5 mm | | **Flex cable (1 conductor)** | 0.14–1.5 mm² (AWG26–AWG16) | | **Flex cable (2 conductors)** | 0.14–0.75 mm² (AWG26–AWG18) | | **Rigid/semi-rigid cable (1 conductor)** | 0.14–2.5 mm² (AWG26–AWG14) | | **Rigid cable (2 conductors)** | 0.14–1.5 mm² (AWG26–AWG16) | | **Tightening torque** | **0.6 N·m** | **Source:** "Relay Output Characteristics — Connection" section, page 10. --- ## 🔷 PROCESSING / TIMING | Parameter | SR1B201BD Value | |---|---| | **Control scheme lines (program size)** | **80 lines** | | **Maximum cycle time** | **8 ms** | | **Input-to-output response time** | **14 to 26 ms** | | **Clock backup (power failure)** | **≥ 150 h at 40°C** | | **Program memory** | **For life — internal EEPROM** | | **Clock drift** | **≤ 6 seconds/month** | | **Time delay accuracy** | **±12 ms or ±0.5% of time displayed** | **Source:** "Processing Characteristics" table, page 11. --- ## 🔷 POWER SUPPLY (for context) | Parameter | Value | |---|---| | **Nominal supply voltage** | **24 Vdc** | | **Voltage limits** | **19.2 to 30 V (including ripple)** | | **Nominal input current** | **130 mA** | | **Heat dissipation** | **2.9 W** | | **Hold-up time (power loss)** | **≤ 1 ms, repeated 20 times** | | **Polarity inversion protection** | **Yes** | **Source:** "Supply Characteristics Vdc" table, page 9 — column SR1-B201BD. --- ## 📄 Source Document **Full citation:** Schneider Electric, *Zelio-Logic™ Relays SR1, File 8501*, catalog document, October 2003 (ref: 8501CT0001R1/03). **URL:** `http://5.imimg.com/data5/SELLER/Doc/2024/3/402848026/VR/PZ/FO/64267321/schneider-sr1-b201bd-logic-relay.pdf` **Relevant pages:** 9 (supply + discrete inputs), 10 (analog inputs + relay outputs), 11 (processing), 13 (ordering/ID), 14–15 (wiring diagrams).